Module 1

0.2 With a neat diagram, explain the general configuration and major components of SCADA system.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Explain single master, multiple submaster multiple remote configuration with a neat diagram.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Explain the key concept of reliable operation of Power System.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1
Show 2 Backup Questions

Explain the Operating States of Power System with a neat diagram. List out the objectives of Power System Control. Explain the Various Controls involved.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

With a neat diagram, explain the components of Remote Terminal Unit (RTU) for power system SCADA.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Module 2

4 distinct question groups available in the collected papers. More exam sessions are being collected.

Derive the mathematical model of Generator load model and draw the complete block diagram representation of load frequency control of an Isolated Power system.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Derive the Mathematical Model of speed governing system.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Draw the schematic diagram of steam turbine speed governing system and explain the functions of the various components.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1
Show 1 Backup Question

Two generators rated 200 MW and 400 MW are operating in parallel. The droop characteristics of their governors are 4% and 5% respectively from no load to full load. Assuming that the generators are operating at 50 Hz at no load. How would a load of 600 MW be shared between them? What will be the system frequency at this load? Assume free governor operation. Ca Write short notes on Turbine Model.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Module 3

4 distinct question groups available in the collected papers. More exam sessions are being collected.

Derive a mathematical model of a Tie line interconnecting two control areas 1 × 2. Then draw the block diagram representation of a two - area interconnected system with Primary Control loop.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 1

Describe the effect of the speed governor dead band on AGC.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 2

Explain the decentralized control in interconnected power system.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 2
Show 1 Backup Question

Explain the function of important components and their function of automatic voltage regulator of a generator with a neat diagram. Q.6 a Esgsin to had regpey onasu nin Gosmin ae Conts r7 1,2 (GRCs) diagram.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1Original question scan, part 2
1 exam session
  • June-July-2026 · PDF page 1

Module 4

3 distinct question groups available in the collected papers. More exam sessions are being collected.

Explain the different methods of voltage control by reactive power injection.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 2

Explain the generation and absorption of reactive power in electrical power Three generating stations are connected to a common bus bar X, as shown in fig. Q. 7 (b). For a particular system load, the line voltage at the bus bar falls by 2kv. Calculate the reactive power injection required to bring back the voltage to the original value. All PU values are on a 500 MVA base. 550г jor1 P.u 20007 5000 j502 275KV 1 502 182 KV uno 5o.1 p.o B275kv Fig. Q.7 (b)

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 2

In the radial transmission system shown in fig.Q. 8 (b) all P.U values are referred to the voltage bases shown is 100 MVA. Determine the power factor at which the generator must operate. 160 km 0•1PU D 0004Po c 48Km 0•IPU B OlfuA чеrе- reue toad OIPU → Somw O-IP.0 шли 1Pf оо4ро р0 132kv 11kv 275 kv 200MW 0•8 Pf lag Fig. Q.8 (b)

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 2

Module 5

4 distinct question groups available in the collected papers. More exam sessions are being collected.

dl. With the help of flow chart, explain the AC Power flow security analysis with contingency case selection.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 3

Explain the formulation and state estimate using linear least square estimation. Also explain the condition for observability in least square estimation.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 3

List and explain the major functions involved in system security. VD - VD - VD - VD - VD - VD - 05-06-2026 01:32:23pm 05-06-202ł VD - VD - VD - VD - VD - VD - VD - VD - VD

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 3
Show 1 Backup Question

With a neat flow chart, explain contingency analysis for generation outage using generation shift sensitivity factors.

OCR transcription · Wording, symbols, or figures may be incomplete.

View question scan & diagramsOriginal question scan, part 1
1 exam session
  • June-July-2026 · PDF page 3